Monday, October 6

Music New 15 Mode Indicator Aiyima Vu Audio Level Meter Agc Speed Case Vfd Adjustable

Black Friday Audio Video Promotion Sale Goods Collections with Free Shipping Delivery from Trusted Store Goods Choice Super Consumer Review provide Music New 15 Mode Indicator Aiyima Vu Audio Level Meter Agc Speed Case Vfd Adjustable.
Music New 15 Mode Indicator Aiyima Vu Audio Level Meter Agc Speed Case Vfd Adjustable Rating: 3.0 out of 5
Get Discount Now! Only US $33.42/piece at this time. Hurry buy Now before back to normal price! Normal price US $38.86 or you can Check price now. Dont waste your time. Buy Now only at AiyimaTechnology Store Trusted Seller Store!

Quality products ensure your life extra comfy when utilizing it. If you are interested to purchase it, you can straight get in touch with the sales to get even more details concerning this high quality item.

This item is very unique, made with high quality products absolutely sturdy for use in a long duration. Prior to you use it, make certain you review the overview very carefully. Do not slip up when using it. Quality products ensure your life more comfy when using it. If you are interested to get it, you could straight speak to the sales to get even more info concerning this top quality item.

Product description:

VFD Operating instructions:

Features:

• Dedicated VFD spectrum display, Resolution 25 X 15.

• Support 32HZ-16KHZ frequency sweep , Ensure the accuracy of each band.

• The falling speed of the light bar, the holding time and the falling speed of the peak can be adjusted separately.

• Real output and smooth output I/ smooth output II selection

• Clock brightness can be adjusted 3 levels.

• Extended function interface(Infrared, sound source selection, volume motor control, volume key, volume display, standby control)

• Accurate clock display function (This function is entered after 10 seconds without signal input and key operation).

(SD2405AL built-in crystal oscillator, the chip can ensure that the clock accuracy is + 5ppm (at 25 + 1 degrees Celsius), the annual error is less than 2.5 minutes)

• Software AGC + custom output curve, In order to ensure that the input signal in a large range of output effect is ideal.

• Custom frequency band display to ensure that even the 25 segment, can fully display the audio frequency range.

Never exceed 5V , 5V/2A is recommended.

Please use a regular USB charger for power. Please do not use computer USB power supply.

Specific operation:

Normal mode:

1. Single click

UP- Mode change

DOWN- Mode change

OK - Bottom line display or no in spectrum mode

2. Double-click

OK- Switching real / smooth I/ smooth II output

3. Three-click

OK- Menu effect switch, right -left transition / up - down transition / mid folding open

4. Four-click

OK - Volume display function on or off

5. Five-click

OK - Switch the extended port output level, high or low level

6. Composite key

UP+DOWN -2 Seconds

A.(In the spectrum mode)

The external ports are switched on or off (including infrared interface, audio source selection interface, volume motor control interface, volume key interface, standby control interface).

B.(In the clock mode )

Switch the clock display effect.

UP+DOWN+OK -2 Seconds,Enter the screen self-test program, press the OK button 1 second to exit.

UP+DOWN+OK-5 Seconds,Enter infrared learning function, press OK button to exit in 1 second

UP+DOWN+OK-10 Seconds,Infrared code recovery factory settings (the default is Tmall infrared remote control).

7. Long press button

UP - Clock mode(or standby mode)Brightness increase

(Note, if you need to increase to the brightest level, press for about 10 seconds, if the standby brightness is too high, it will cause uneven of VFD, the highest brightness level is not recommended).

DOWN-Clock mode(or standby mode)Brightness reduction

Speed setting mode: (In normal mode, press the button for 2 seconds to enter, press the button for 2 seconds to exit) .

OK

a.The falling speed of the light bar (15 optional)

b.The holding time of the peak (15 optional)

c.The falling speed of the peak (15 optional)

d.Output selection (Real output / smooth I output/ smooth II output) Loop in these functions.

UP - Time increases, Speed decreases

DOWN - Time decreases, Speed increase

Clock Setting mode :(In normal mode, press the button for 5 seconds to enter, press the button for 2 seconds to exit) .

Single click

OK - Switching hours / min / sec / year / month / day

UP- Hours / minutes / sec / year / month / day increase.

DOWN- Hours / min / sec / year / month / day decrease.

Other function operation:

Factory default

OK -10 Seconds.

Important notes:

1.Because of the working conditions of VFD, there is a DC high voltage of about 38V, so dont touch the VFD pins when it is working.

2.Because of the characteristics of VFD, long working brightness will be attenuated, so it will become uneven, is a normal phenomenon.

3.Because the clock module is selected parts, if there is no clock module installed, then the relevant clock function instructions are invalid.

4.When there is no clock function, no signal input and button operation, will enter standby state and display standby characters, in the external port closed setting , after 1 minutes it will close the filament power supply and VFD high voltage. Enter deep standby status. Auto wakeup when there is a signal input or press button operation.

The spectrum center frequency band is shown in the figure.

Package included:

1PC


Return Policy

If the product you receive is not as described or low quality, the seller promises that you may return it before order completion (when you click "Confirm Order Received" or exceed confirmation timeframe) and receive a full refund. The return shipping fee will be paid by you. Or, you can choose to keep the product and agree the refund amount directly with the seller.
N.B.: If the seller provides the "Longer Protection" service on this product, you may ask for refund up to 15 days after order completion.

Seller Service

On-time Delivery: If you do not receive your purchase within 60 days, you can ask for a full refund before order completion (when you click "Confirm Order Received" or exceed confirmation timeframe).
Music New 15 Mode Indicator Aiyima Vu Audio Level Meter Agc Speed Case Vfd Adjustable

No comments:

Post a Comment

Texture Cover Handle Switch Game Rubber Protector Case Silicone Soft Dedicated Sleeve Host

Big Sale Camera Photo Promo Goods with Express Shipping Delivery from Goods Choice Good Customer Comment provide Texture Cover Handle Swit...

Popular Posts